Stationary or automatic smoke curtain D 120 / DH 120.

Smoke curtain D 120 / DH 120

994 0006
Užsakoma
Price on request

Pateikite savo kainos pasiūlymą – jį įvertinę, mūsų vadybininkai susisieks su Jumis ir aptars galimas įsigijimo sąlygas.


Užsakoma prekė. Apie prekę teiraukitės telefonu ar el. paštu: Kontaktai
Siūlykite savo kainą.
 

Smoke curtain D 120 / DH 120

Extremely lightweight flexible automatic or stationary smoke curtains in classes D and DH are a proven solution for limiting the spread of smoke.

The modular design allows you to connect curtains and form a barrier of unlimited length and shape. The low weight of one module makes it easy to adapt to the shape of the ceiling and install.

Main features

  • Extremely lightweight construction
  • Automatic versions ASB1, ASB2, ASB3, ASB4
  • Stationary SSB versions
  • Quick installation
  • Integration with fire alarm system
  • Barriers of unlimited length can be formed

Technical specifications

Product type Automatic and stationary smoke curtains
Direction of movement Stationary/vertical
Purpose Protection against smoke spread and control of its direction
Class D 120, DH 120
Certificates CE 1396-CPR-0125, issued by Fires [No. 1396]; CE 1488-CPR-0112/W, issued by ITB [No. 1488]
Standard EN 12101
Curtain weight 0.75 kg/m²
Dimensions Unlimited
Minimum installation dimensions ASB: min. 200 mm ceiling / lintel; SSB: min. 30 mm ceiling / lintel

Available options and additional equipment

  • Smoke detectors
  • Emergency opening button
  • Optical and audible signaling devices
  • RAL color painting
  • Anti-corrosion protection/painting C3–C5
  • Stainless steel version

Adaptation

The product is suitable for industrial, commercial, logistics, warehousing, infrastructure and special purpose facilities that require a certified fire, smoke control, acoustic, ballistic or electromagnetic shielding solution. Specific dimensions, configuration and installation conditions are selected according to the project.

Design and installation

The solution must be selected based on the opening dimensions, partition type, required resistance class, installation conditions, control logic and integration with building security systems. Additional alarm, security, anti-corrosion and control options are available.